Delivers accurate formation resistivity measurements regardless of wellbore geometry in conductive-mud environments


Applications

  • Determining formation conductivity in conductive-mud environments
  • Determining water saturation (Sw)
  • Providing well-to-well correlation
  • Identifying moveable fluids and fluid contacts
  • Creating an invasion profile to indicate permeability


Features and Benefits

  • A unique electrode arrangement on the Compact dual laterolog (MDL) tool detects the Groningen effect, which enhances quality control and provides accurate, real-time, deep-resistivity readings.
  • The MDL runs with the Compact microlaterolog (MMR) pad to obtain an independent, shallower data set, which improves the accuracy of flushed-zone resistivity (Rxo) and formation resistivity (Rt) data in complex invasion profiles.
  • Data from the Compact shallow-focused electric (MFE) tool can enhance the vertical resolution of the MDL to 6 in. (0.15 m), which improves thin-bed analysis and reserve estimates.
  • The small diameter of the MDL tool facilitates deployment in wireline or memory mode to mitigate the risk of bridging events and to reduce nonproductive time.
  • The MDL is fully combinable with the Compact array induction (MAI) tool to provide a unique invasion profiling.
  • The tool runs without wireline when used with the Compact memory logging (CML) system.


Tool Description

The Weatherford Compact dual laterolog (MDL) tool provides accurate resistivity measurements in high-contrast conductive-mud environments. The MDL tool provides individually optimized deep- and shallow-penetration curves that share a common 2-ft (0.6-m) vertical resolution. The deep measurement provides the Groningen curve and detects anomalous responses when the tool approaches nonconductive formations, such as salt caps.

Optimized-electrode geometry and digital-measurement sequence control enhance performance over a wide range of mud resistivities (Rm) and hole sizes and virtually eliminate electrode-polarization effects. The voltage reference and simultaneous SP electrodes are incorporated into a stiff bridle at the top of the toolstring to optimize reliability. 


Specifications

Measurement

Data

Deep and shallow resistivity, Groningen, SP

Logging speed

3,600 ft/hr (18 m/min)

Measurement range

0.1 to 40,000 ohm-m

Resolution

1% of measured value

Accuracy

0.00075 s/m or 2% (whichever is greater)

Depth of investigation

Deep: 50.4 in. (1.27 m)
Groningen: 50.4 in. (1.27 m)
Shallow: 16.2 in. (0.41 m)

Borehole fluids

WBM, salt

 

Mechanical

Maximum outer diameter

2.25 in. (57 mm)

Length

29.31 ft (8.93 m)

Weight (air)

109 lb (49 kg)

Maximum temperature

320°F (160°C)

Maximum pressure

15,000 psi (103 MPa)

Maximum borehole diameter

19 in. (483 mm)

Minimum borehole diameter

2.8 in. (70 mm)