Gamma Ray – Casing Collar Locator – Neutron – Inclinometer – Temperature Tool


Provides correlation and formation evaluation information


Applications

  • Through casing porosity
  • Gas identification
  • Wellbore directional survey


Features and Benefits

  • Slim profile for maximum wellbore access
  • Compact array of sensors for evaluation of wellbore and reservoir uncertainty


Tool Description

The Weatherford gamma ray – casing collar locator (CCL) – neutron – inclinometer – temperature tool is a compact tool for through-casing evaluation of certain reservoir parameters that can be accurately correlated and understood together with the well geometry.


Specifications

Ratings and dimensions

Maximum temperature

350°F (177°C) for 4 hours

Maximum pressure

20,000 psi (138 MPa)

Outer diameter

1.69 in. (42.93 mm)

Length

96.46 in. (2450.084 mm) | (M/U length 94.67 in. (2404.62 mm)

Weight

35.0 lb (15.9 kg)

Minimum casing/tubing OD

2.38 in. (60.45 mm)

Maximum casing/tubing OD

7.0 in. (178.0 mm)

Tensile strength*

Tension: 65,000 lb
Compression: 130,000 lb
Torque:150 ft-lb

Measure points

GR: 84.79 in. (2,153.67 mm)
CCL: 42.37 in. (1,076.2 mm)
NEU: 14.67 in. (372.62 mm)
INC: 57.54 in. (1,461.52 cm)
TEMP: 51.48 in. (1,461.52 cm)

*Strengths apply to new tools at 70°F (21°C) and 0 psi.ß

Borehole conditions

Borehole Fluids

Salt, fresh and oil

Logging Speed

Recommended: 60 ft/min (18.2 m/min)
Maximum: 100 ft/min (30.5 m/min) at 0.08 ft (.02 m) sample rate

 

Electrical specifications

Operating V / Current

130V DC at 45 mA

 

Hardware characteristics

 

Gamma Ray

Casing Collar Locator

Neutron

Inclinometer

Sensor Type

Thallium activated sodium iodide crystal

Dual magnet,
center coil

Helium-3 filled neutron detector

3-axis accelerometer

Transmission Type

Digital telemetry

Line wobble
or telemetry

Digital telemetry

Digital telemetry

Data Rate

20 frames / sec at 20 kHz

Combinability

RADII and CBT (bottom only)

Connections

GO top, Source sub bottom (no feedthrough)

Temp Specs

Sensor: RTD (1000) | Trans Type: Digital telemetry | Prim Curve: Temp (°F/C) | Calibration: 2pt linear

 

Measurements


Principle

Natural Gamma Radiation

Magnetic Flux Lines

Thermal Neutron Detector

Gravity Vector

Range

0 to 10,000 cps

2.38 to 7.0 in.
(60.452 to 178.0 mm)

200 to 2,000 cps

± 2 g

Vert resolution

6.0 in. (152.5 mm)

NA

NA

NA

Accuracy (1SD)

± 5%

NA

± 0.07%

± 0.5 degrees

Sensitivity

~0.998 cps/API unit

NA

15 cps/nv

900 lsb/g

Primary curves

GR (API)

CCL (mV)

NEU (API)

Inclination

Secondary

Head voltage, Internal temperature (telemetry only)

 

Temperature measurements

Accuracy (+/-)

0.898°F (0.5°C)

Response time

0.5 seconds

Resolution

0.0018°F (0.001°C)