Gamma Ray – Casing Collar Locator Tool


Provides accurate correlation of log depth to formation gamma ray and casing record.


Applications

  • Real-time depth control of cased hole log data
  • High Temperature wells up to 475°F (246°C)


Features and Benefits

  • Versatile tool for simultaneous acquisition of background gamma ray and casing/tubing collars
  • Compatible with all HD-platform tools


Tool Description

The Weatherford gamma ray and casing collar locator is a combined gamma ray and CCL tool which provides a passive measurement of gamma radiation by means of a sodium iodine scintillation detector and identifies changes of metal thickness by means of a collar locator.

The telemetry gamma ray and casing collar locator is a combined gamma ray and CCL tool with a telemetry control unit which provides a passive measurement of gamma radiation by means of a sodium iodine scintillation detector and identifies changes of metal thickness by means of a collar locator. The telemetry control unit is the communications control center for the logging system. The tool controls the collection of data from the tools below and packages it for the transmission to the surface system.


Specifications

Ratings and dimensions

 

1-11/16 in.

2-3/4 in.

1-11/16 in. Corrosion

2-3/4 in. 6-Pin

1-11/16 in. High Temp

2-3/4 in. 
 High Temp

Maximum temperature

350°F
(177°C) for 4 hours

350°F
(177°C) for 4 hours

350°F
(177°C) for 4 hours

350°F
(177°C) for 4 hours

475°F
(246°C) for 4 hours

475°F
(246°C) for 4 hours

Maximum pressure

20,000 psi
(138 MPa)

20,000 psi
(138 MPa)

20,000 psi
(138 MPa)

20,000 psi
(138 MPa)

20,000 psi
(138 MPa)

20,000 psi
(138 MPa)

Outer diameter

1.69 in.
(42.93 mm)

2.75 in.
(69.9 mm)

1.69 in.
(42.9 mm)

2.75 in.
(69.9 mm)

1.69 in.
(42.9 mm)

2.75 in.
(69.9 mm)

Length

62.4 in.
(1584.96 mm)

54.48 in.
(1383.79 mm)

62.4 in.
(1585.0 mm)

57.6 in.
(1463.04 mm)

94.2 in.
(2392.7 mm)

77.04 in.
(1956.82 mm)

Weight

35.0 lb
(15.9 kg)

55.0 lb
(25.0 kg)

35.0 lb
(15.9 kg)

55.0 lb
(25.0 kg)

42.0 lb
(19.1 kg)

65.0 lb
(29.5 kg)

Minimum casing/tubing OD

2.38 in.
(60.45 mm)

4.5 in.
(115.0 mm)

2.38 in.
(60.5 mm)

4.5 in.
(115.0 mm)

2.38 in.
(60.5 mm)

4.5 in.
(115.0 mm)

Maximum casing/tubing OD

7.0 in.
(178.0 mm)

7.0 in.
(178.0 mm)

7.0 in.
(178.0 mm)

7.0 in.
(178.0 mm)

7.0 in.
(178.0 mm)

7.0 in.
(178.0 mm)

Tensile strength*

Tension: 65,000 lb Compression: 130,000 lb Torque:150 ft-lb

Tension: 65,000 lb Compression: 130,000 lb Torque:150 ft-lb

Tension: 65,000 lb Compression: 130,000 lb Torque:150 ft-lb

Tension: 65,000 lb Compression: 130,000 lb Torque:150 ft-lb

Tension: 65,000 lb Compression: 60,000 lb Torque:150 ft-lb

Tension: 65,000 lb Compression: 130,000 lb Torque:150 ft-lb

Measure Points

Gamma Ray: 6.84 in. (173.74 mm) Casing Collar Locator: 48.96 in. (1243.58 mm)

Gamma Ray: 10.68 in. (271.27 mm) Casing Collar Locator: 43.56 in. (1106.42 mm)

Gamma Ray: 6.84 in. (173.74 mm) Casing Collar Locator: 48.96 in. (1243.58 mm)

Gamma Ray: 30.96 in. (786.38 mm) Casing Collar Locator: 46.92 in. (1191.77 mm)

Gamma Ray: 14.76 in. (374.90 mm) Casing Collar Locator: 80.88 in. (2054.35 mm)

Gamma Ray: 17.04 in. (432.82 mm) Casing Collar Locator: 65.28 in. (1658.11 mm)

*Strengths apply to new tools at 70°F (21°C) and 0 psi.

 

Borehole conditions

 

1-11/16 in.

2-3/4 in.

1-11/16 in. Corrosion

2-3/4 in. 6-Pin

1-11/16 in. High Temp

2-3/4 in.     High Temp

Logging speed

Recommended: 60 ft/min. (18.2 m/min) Maximum: 100 ft/min. (30.5 m/min) at 0.08 ft (.02 m) sample rate

Tool positioning

Centralized | Eccentralized

 

Hardware characteristics (all configurations)

 

Gamma Ray

Casing Collar Locator

Sensor type

Thallium Activated Sodium Iodide Crystal

Dual Magnet, Center Coil

Transmission type

Analog Pulse or Telemetry

Line Wobble or Telemetry

Data rate

20 frames / sec @ 20 kHz

Combinability

Corrosion Platform

Connections

GO Top / GO Pin Bottom

 

Measurements (all configurations)

Principle

Natural Gamma Radiation 

Magnetic Flux Lines 

Range

0-10,000 cps

4.5 to 7.0 in.
(115.0 to 178.0 mm)

Resolution

6.0 in. (152.5 mm)

NA

Accuracy (1SD)

± 5%

NA

Sensitivity

≈ 1.5 cps per API Unit

NA

Primary curves

GR (API)

CCL (mV)

Secondary curves

Head Voltage, Internal Temperature (Telemetry Only)


Calibrations (all configurations)

Primary

Houston API Pits 

Wellsite Verifier

Thorium Blanket

 

Ratings and dimensions (Telemetry)

 

Telemetry gamma ray and CCL 2-3/4 in.

1-11/16 in. HD

2-3/4 in. HD

Maximum temperature

347°F (175°C)

Maximum pressure

15,000 psi (103.4 MPa)

Outer diameter

2.75 in. (70.0 mm)

1.69 in. (43.0 mm)

2.75 in. (70.0 mm)

Length

47.69 in. (1,211.0 mm)

31.25 in. (794.0 mm)

36.7 in. (933.0 mm)

Weight

44.6 lb (20.2 kg)

13.8 lb (6.3 kg)

34.0 lb (15.6 kg)

Measure points

Gamma Ray: 8.43 in. (214.0 mm)
Casing Collar Locator: 39.92 in. (1,014. 0 mm)

Gamma Ray: 6.0 in. (152.0 mm)
Casing Collar Locator: 23.6 in. (600.0 mm)

Gamma Ray: 8.48 in. (215.0 mm)
Casing Collar Locator: 28.9 in. (735.0 mm)

Materials

Corrosion resistant materials used throughout

 

Hardware characteristics (Telemetry)

 

Telemetry gamma ray and CCL 2-3/4 in.

1-11/16 in. HD

2-3/4 in. HD

Range

1-65,000 cps

Resolution

1 cps

Accuracy

10%

Sensitivity

(nominal) 1 count / API

 

Measurements (Telemetry)

 

Telemetry gamma ray and CCL 2-3/4 in.

1-11/16 in. HD

2-3/4 in. HD

Voltage

300 V DC

50 V DC
19 V DC

Current

Load dependent

10 mA
24 mA

Tool bus rate

500 kbps

Uplink rate

150 kbps

Downlink rate

16 kbps

Gamma Ray – Casing Collar Locator Tool

Reach out to optimize reservoir performance

Please fill in the form below for more information on our comprehensive and high-resolution technologies. You will hear from one of our wireline representatives shortly.