RADii® Cement-Bond Tool - Medium Diameter


Identifies cement channeling and generates traditional cement bond log and variable-density log



Applications

  • Cement-bond quality
  • Formation isolation
  • Cement channeling


Features and Benefits

  • Fully Probe® high-speed digital (HD) platform compatible
  • Full SRO and memory capability
  • Storable master calibration in tool memory for retrieval when no free pipe is encountered in the well
  • High-temperature (HT) version for hostile environments


Tool Description

The Weatherford medium diameter RADii segmented cement-bond tool uses a single ceramic transmitter, an eight-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map enabling cement-channeling identification while the single receiver generates the traditional cement-bond log (CBL) and a variable-density log (VDL).

The medium-diameter RADii segmented cement-bond tool comes in three configurations: standard, with temperature sub, and HD.


Specifications

Ratings and Dimensions

 

Standard

With Temperature Sub

HD

Maximum temperature

350°F (177°C)

Maximum pressure

20,000 psi (138 MPa)

15,000 psi (103.4 MPa)

Outside diameter

2.75 in. (69.85 mm)

Length

8.73 ft (2.66 m)

9.39 ft (2.86 m)

8.73 ft (2.66 m)

Weight

93 lb (42.18 kg)

Tensile strength

Tension: 50,000 lb
Compression: 15,000 lb

Casing/tubing OD

Min: 4.5 in. (115 mm)
Max: 11.6 in. (295 mm)

Materials

Alloy steel (stainless also available)

Corrosion resistant materials used throughout

SST

Measure points

Amplitude, TT: 4.3 ft (1.3 m)
VDL, signature: 3.3 ft (1.0 m)

Amplitude, TT: 4.3 ft (1.3 m)
VDL, signature: 3.3 ft (1.0 m)
Borehole temp: 6.8 ft (1.98 m)

Amplitude, TT: 4.3 ft (1.3 m)
VDL, signature: 3.3 ft (1.0 m)

 

Borehole Conditions

 

PTX

HD/Memory

HD

Borehole fluids

OBM, WBM

Tool positioning

Centralized with one each centralizer above and below

Logging speed

Recommended: 60 ft/min (18.2 m/min)
Max: 100 ft (30.5 m)/min at 0.08 ft (.02 m) sample rate

 

Electrical

 

Standard

With Temperature Sub

HD

Current

45 mA at 130 V

45 mA at 130 V

65 mA at 50 V (SRO)
65 mA at 19.2 V (memory)

 

Calibration

 

Standard

With Temperature Sub

HD

Primary

5.5 in. (13.97 cm) pressurized calibration tank

Wellsite

Free pipe, stored calibration tank waveforms on demand


Hardware characteristics

 

Standard

With Temperature Sub

HD

Source type

One piezoelectric crystal fired at 20 kHz, 50 msec intervals

Sensor type

Omni receiver: One 20 kHz piezoelectric
Radial receiver: One 8-segment 20 kHz piezoelectric

Connections

Top: 1 3/16 in. 12-P GO box
Bottom: 1 3/16 in. 12-P GO box

Top: 1 3/16 in. 12-P type-A
GO box
Bottom: 1 3/16 in. 12-P type-A GO box

Top: GOI box
Bottom: GOI pin

Combinability

GR, CCL, ProMac™, iQ™, Temperature

GR, CCL, single- or dual-spaced neutron

GR, CCL, ProMac™, iQ™, Temperature

Acquisition mode

SRO

SRO

SRO with TCU
Memory with MLT

Fire rate

20/sec

Waveform

Analog: 3 ft (.9 m), 5 ft (1.5 m)
Digital: telemetry data

Record time

1,480 microseconds for each receiver
500 microseconds for each sector


Measurements (all configuration except where noted)

 

E1 Peak Amplitude

Sonic Waveform

Principle

Sonic wavetrain attenuation

Range

200 to 1,500 us

Resolution

3 ft/0.9 m

5 ft/1.5 m

Precision (1 SD)

< 1 mV

N/A

Primary curves

Amplitude: 3ft (.9 m) 
Individual sector amplitudes: (3 ft) (.9 m)
TT: 3 ft (.9m) 
VDL 5 ft (1.5 m) 
Borehole temperature*: 6.48 (1.98 m)

Secondary curves

Probe telemetry and Temperature: Head Voltage, Internal Temperature 
HD: Head voltage, internal temperature, accelerometer, volume

*Temperature sub configuration only